LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

> Back to components

Construction assembly A2185

Lignum ID-№
A2185
Catalog number
A.3.01.DE350A
Source of construction assembly
Tschopp, Year 2017
Base structure
BRESTA Solid Timber System
Paneling
Substructure rigid screwed
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 434
Construction height
390 mm
Weight
285 kg/m2
U-value
≈ 0.261 W/m2K
GWP
42.03 kg CO2-eq/m2
Type sound insulation
Calculation
Ceiling consisting of a basic construction of BRESTA Solid Timber System, without sheathing, simple ceiling covering. stiff screwed substructure, without dampening in the supporting structure, with cavity insulation in the supporting structure. Without dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 60 MN/m³ and with cement screed.
Values of airborne sound insulation
Rw 65 dB
C -3 dB
C50-3150 -5 dB
Values of footfall sound insulation
Ln,w 51 dB
CI 0 dB
CI50-2500 5 dB

Graphic

Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Additional insulation: EPS-T 30mm mit dynamischer Steifigkeit s' von ≤ 22 [MN/m³]
Bond: no composite action
Supporting structure: Bresta Solid timber panel
Cavity dampening: Cellulose: Loose; not monitored
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=40mm
Ceiling covering 1st layer: OSB3 panel

Assembly

Comment Cavity damping reduces cavity resonances. The relevant parameter is not bulk density but airflow resistivity (5–50 kPa·s/m²). The insulation material must fill at least 70% of the cavity height and 80% of the cavity width. See Lignum publication «Schallschutz im Holzbau», Section 4.5.

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Flooring Fllor Generic product 15 kg/m2 - - 11.013 91.011
On-lying material Cement screed Generic product 176 kg/m2 - - 04.006 91.136
Impact sound insulation Wood fiber generic product Generic product 3.2 kg/m2 - - 10.009 91.051
Additional insulation EPS-T 30mm mit dynamischer Steifigkeit s' von ≤ 22 [MN/m³] Sager, Swisspor 0.3 kg/m2 - - 10.004 91.151
Bond no composite action - - - - - - -
Supporting structure Bresta Solid timber panel Tschopp 78.4 kg/m2 07.011.02 91.052
Cavity dampening Cellulose: Loose; not monitored Generic product - - - 10.010 91.046
Bond Stiff, execution of the prior art. - - - - - - -
Battens / profiles Wood lath b=40mm Label swiss wood, Generic product 3.1 kg/m2 07.011 91.052
Ceiling covering 1st layer OSB3 panel Stora Enso, Swiss Krono Group, Pfleiderer, Binderholz, Novatop, Pius Schuler 9.8 kg/m2 - - 07.013 91.145

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
88727
UBP'21/m2
A1-A3 + C1-C4
 
┣
Environmental impact points from production (UBP_pro)
73347
UBP'21/m2
A1-A3
 
┗
Environmental impact points from disposal (UBP_dis)
15287
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1033.34
kWh oil-eq/m2
A1-A3 + C1-C4
 
┣
Primary energy from production (PE_pro)
1014.15
kWh oil-eq/m2
A1-A3
 
┃
┣
Primary energy production, energetically consumed (PE_E_pro)
506.29
kWh oil-eq/m2
A1-A3
 
┃
┗
Primary energy production, materially bound (PE_M_pro)
511.30
kWh oil-eq/m2
A1-A3
 
┗
Primary energy from disposal (PE_dis)
18.98
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
911.28
kWh oil-eq/m2
A1-A3 + C1-C4
 
┣
Renewable primary energy from production (PE_RT_pro)
909.94
kWh oil-eq/m2
A1-A3
 
┃
┣
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
408.19
kWh oil-eq/m2
A1-A3
 
┃
┗
Renewable primary energy from production, materially bound (PE_RM_pro)
501.76
kWh oil-eq/m2
A1-A3
 
┗
Renewable primary energy from disposal (PE_RT_dis)
0.99
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
125.47
kWh oil-eq/m2
A1-A3 + C1-C4
 
┣
Primary energy not renewable from manufacturing (PE_NRT_pro)
107.63
kWh oil-eq/m2
A1-A3
 
┃
┣
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
98.19
kWh oil-eq/m2
A1-A3
 
┃
┗
Primary energy not renewable from production, materially bound (PE_NRM_pro)
9.49
kWh oil-eq/m2
A1-A3
 
┗
Primary energy not renewable from disposal (PE_NRT_dis)
17.99
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
42.03
kg CO2/m2
A1-A3 + C1-C4
 
┣
Greenhouse gas emissions from manufacturing (GWP_pro)
34.65
kg CO2/m2
A1-A3
 
┗
Greenhouse gas emissions from waste disposal (GWP_dis)
7.35
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
155.82
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
42.50
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)